Contact Us

IO-Link master (PNIO/MOD) ICE3-8IOL-G65L-V1D

· PROFINET IO, Modbus/TCP and OPC UA Support
· Web-based configuration of module and IO-Link devices
· Integrated IODD storage for more than 100 IODDs
· Downloadable module configuration
· M12 L-coded power connector

Product Details

Product Description

PROFINET IO IO-Link master with 8 inputs/outputs

General specifications

UL File Number

E360395

Indicators/operating means

LED indication

see manual

Rotary switch

Setting the IP address

Electrical specifications

Rated operating voltage

20 ... 30 V DC

Nominal voltage

24 V DC

Current consumption

typ. 120 mA

Current loading capacity

Max. 2 x 16 A per module
(Loop-through current via L-coded power supply)
Total current: max. 6.7 A per module

Galvanic isolation

between US and UA

Interface 1

Interface type

Industrial Ethernet

Physical

M12, D-coded

Protocol

PROFINET IO with media redundancy protocol (MRP) + Modbus TCP + OPC UA + MQTT
Modbus max PDI: 33 times / sec
OPC UA max PDI update rate: 20 times / sec
MQTT max PDI update rate: 10 times / sec

Transfer rate

10/100 Mbps

Inputs/Outputs

Number/Type

8 x IO-Link Class A (X1 – X8)
Configurable as:
Max. 8 IO-Link and 8 digital inputs
Max. 16 digital inputs
Max. 8 digital inputs and 8 digital outputs
short-circuit protected

Sensor supply

Port 1: max. 1.6 A Via L+ (pin 1)
Port 3: max. 1 A via L+ (pin 1)
Ports 2 and 4 – 8: max. 500 mA per port via L+ (pin 1)

Output current

max. 200 mA Per port via C/Q (pin 4)

Directive conformity

Electromagnetic compatibility

 

Directive 2014/30/EU

EN 61000-6-2 , EN 61000-6-4

Standard conformity

Degree of protection

EN 60529

Fieldbus standard

Type 1 according to IEC 61131-2, EN 61131-9

Electrical safety

CSA C22.2 No. 61010-1-12
UL 61010-1, IEC 61010-2-201

Emitted interference

EN 61000-6-4, FCC Part 15 Subpart B, ICES-001, AS/NZS CISPR 11

Noise immunity

EN 61000-6-2 , EN 61131-2 , EN 61131-9

Shock resistance

EN 60068-2-27

Ambient conditions

Ambient temperature

-25 ... 70 °C (-13 ... 158 °F)

Storage temperature

-40 ... 85 °C (-40 ... 185 °F)

Relative humidity

max. 95 %

Altitude

0 ... 2000 m

Shock and impact resistance

15g, 11ms, half-sine

Mechanical specifications

Degree of protection

IP67

Connection

Power Supply M12, L-coded
Fieldbus M12, D-coded
Inputs/Outputs M12, A-coded

Material

 

Housing

Molded Polyamide 66

Mass

454 g

Tightening torque, fastening screws

8 Nm

Tightening torque, cable gland

0.6 Nm

Dimensions

 

Height

212 mm

Width

65 mm

Length

29.8 mm

Construction type

Field housing